Heidelberg ProSetter

 Error:             Description:                                                        More Details:
 0   Recorder is ready for operating  
 1   Internal Error   An error occurred in the program sequence 
 2   Internal Error   An error occurred in the program sequence
 12   Internal Error   Internal communication error
 35   An error occurred in a database.   The specified record is not available.
 36 An error occurred in a database. The specified error got a different type.
 37 An error occurred in a database. The length of the value of the specified error is to long for the delivered buffer
 38 An error occurred in a database. The length of the buffer of the specified record is to short for the delivered value
 40 An error occurred in a database The insertion of a record into a database is not possible
 41 An error occurred in the file system A file could not be opened
 42 An error occurred in the file system A file could not be closed
 43 An error occurred in the file system A file could not be seeked
 44 An error occurred in the file system A file could not be written
 45 An error occurred in the file system A file could not be read
 48 An error occurred while allocating memory Memory could not be allocated
 49 An error occurred while parsing a source A syntax error is occurred
 94 Internal system error Error using operating system function
 95 Internal system error Error using operating system function
 96 Internal system error Error using operating system function
 97 Internal system error Error using operating system function
 98 Internal system error Error using operating system function
 99 Internal system error Error in file operation
 100 Internal system error Error in file operation
 101 Internal system error Error in file operation
 102 Internal system error Error in file operation
 103 Internal system error Error in file operation
 104 Internal system error Error in file operation
 105 Internal system error Error in file operation
 106 Internal system error Error in file operation
 107 Internal system error Error in file operation
 108 Internal system error Error in file operation
 109 Internal system error Error in file operation
 110 Internal system error Error in file operation
 111 Internal system error Error in file operation
 112 Internal system error Error using operating system function
 113 Internal system error Error using operating system function
 114 Internal system error Error using operating system function
 115 Internal system error Error using operating system function
 116 Internal system error Error using operating system function
 117 Internal system error Error using operating system function
 118 Internal system error Error using operating system function
 119 Internal system error Error using operating system function
 120 Internal system error Error using operating system function
 121 Internal system error Error using operating system function
 122 Internal system error Error using operating system function
 123 Internal system error Error using operating system function
 124 Internal system error Error using operating system function
 126 Internal system error Error in file operation
 128 Internal system error Error in file operation
 129 Internal system error Error in filebox
 130 Internal system error Error in filebox
 133 Communication error Speedway communication error
 134 Communication error Speedway communication error
 135 Internal system error Error using operating system function
 136 Internal system error Error using operating system function
 146 Internal system error Internal communication error
 147 Internal system error Internal communication error
 148 Internal system error Internal communication error
 149 Internal system error Internal communication error
 150 Internal system error Internal communication error
 151 Internal system error Internal communication error
 152 Internal system error Internal communication error
 153 Internal system error Internal communication error
 154 Internal system error Internal communication error
 155 Internal system error Error using operating system function
 156 Internal system error Error using operating system function
 157 Internal system error Error using operating system function
 158 An error occurred in a database The erasing of a record out of a database is not possible
 163 Internal system error Error in file operation
 164 Internal system error Error in file operation
 170 An internal hardware error occurred FPGA busy error
 171 An internal hardware error occurred FPGA detection error
 172 An internal hardware error occurred FPGA initialization error
 173 An internal hardware error occurred FPGA busy error
 174 An internal hardware error occurred FPGA frame data error during configuration
 175 An internal hardware error occurred FPGA length count error
 220 An error occurred in a database A file which should be copied does not exist
 221 An error occurred in a database A file could not be deleted
 222 An error occurred in a database A file could not be copied
 223 An error occurred in a database A directory could not be created
 224 An error occurred while parsing a source A serious syntax error is occurred
 225 An error occurred while parsing a source A serious syntax error is occurred
 234 Internal error Operating system error
 235 Internal error Operating system error
 237 An internal hardware error occurred Communication error on the SPI Bus
 282 Internal system error Error in Package
 283 Internal system error Error in Package
 284 Internal system error Error in FPGA box
 285 Internal system error Error in FPGA box
 293 The current machine type is usable for test purposes only The current machine type is usable for test purposes only
 294 The current machine type is invalid The current machine type is invalid
 295 The current machine variation is invalid The current machine variation is invalid
 313 Internal system error Operating system error
 314 Internal error Operating system error
 319 An error occurred while parsing a source A semantics error occurred
 320 An error occurred while parsing a source Simple semantics error
 321 An error occurred while parsing a source Serious semantics error
 322 Switch off sequence initiated Fast switch off sequence initiated
 323 Fast switch off sequence initiated A second switch off command was received. Only data will be saved before switch 
 324 An error occurred in the parameter database The parameter configuration file does not exist
 400 Internal error Undefined error
 401 Internal error Undefined error
 402 Internal error Wrong magic number received with the data
 403 Internal error Buffer size error
 404 Internal error Checksum error
 405 Internal error Error after select() function
 406 Internal error select() timeout
 407 Internal error Error after ioctl() function
 408 Internal error Not enough buffer for download
 409 Internal error Not enough buffer for download
 410 Internal error Not enough FLASH memory
 411 Internal error Unknown FLASH vendor
 412 Internal error Unknown FLASH module
 413 Internal error Invalid FLASH map
 414 Internal error FLASH not ready
 415 Internal error Error clearing the FLASH
 416 Internal error Error clearing the FLASH
 417 Internal error Error clearing the FLASH
 418 Internal error Error clearing a FLASH sector
 419 Internal error Error clearing a FLASH sector
 420 Internal error Error checking a FLASH sector
 421 Internal error Timeout programming the FLASH
 422 Internal error FLASH not ready
 423 Internal error Error comparing the FLASH after write operation
 424 Internal error Error connecting with an interrupt
 425 Internal error Error activating an interrupt
 426 Internal error Out of init error memory
 427 Internal error Error initializing the hardware
 428 Internal error Error reading from FLASH
 429 Internal error Error writing to FLASH
 430 Internal error Error after open() function
 431 Internal error Error after close() function
 440 Internal system error Error using operating system function
 441 Internal system error Error using operating system function
 442 Internal system error Error using operating system function
 443 Internal system error Error using operating system function
 3001 The ventilator for the central electronics is defective! Forcing power off of the recorder Electronics ventilator monitor reports an error. You cannot continue operation. Powering down the recorder
 3002 Wrong Bacher punch configuration Bacher Configuration parameter (PID 21958) is wrong. The bit map of the Bacher Configuration (PID 21958) must be a subset of the bit map of the Punch Configuration (PID 766)
 3003 The ventilator of the air filter is not working. There will be a loss of recorder quality due to dirty mirrors if this error occurs over a longer period of time The ventilator of the air filter is not rotating or the phase sequence sensor is defective
 3004 The air filter is used and must be replaced. There will be a loss of recorder quality due to dirty mirrors if this error occurs over a longer period of time The sensor for the air filter reports that the filter is used
 3005 Max. output level of the optical head is not enough to image in the selected mode Max. output level of the optical head is not enough to image in the selected mode
 3006 Max. output level of the optical head is not enough to image in the selected mode Cannot end an action in the recorder because of a preceding error or power-off function
 3007 Punch setting doesn't match punch configuration RIP punch action doesn't match punch configuration
 3008 ATTENTION: Plate lost in device! Do NOT correct error A plate was probably lost in the device during initialization. Error correction is illegal in this present state
 3009 Internal communication error Communication with an internal assembly (e.g. Optic) failed
 3010 Internal communication error Communication with with the Autoloader failed
 3011 Error in the slow scan unit Could not find resolution for calculation of an imaging ramp
 3012 Network addresses (IP addresses) conflict The two network addresses of the recorder must not come from the same network
 3014 An error occurred in the mirror motor unit The time monitor reports timeout during the spin-up phase of the mirror motor
 3015 An error occurred in the mirror motor unit The time monitor reports timeout during the spin-down phase of the mirror motor
 3016 An error occurred in the air supply unit The air safety switch is not closed
 3017 An error occurred in the air supply unit The mirror air cooler temperature is to high
 3018 An error occurred in the air supply unit Communication error on the I2C-Bus
 3019 Internal communication error The air pump did not start
 3020 An error occurred in the air supply unit The focus stepping motor cannot find the zero position
 3021 An error occurred in the optic unit The focus stepping motor cannot find the zero position
 3022 A parameter set-up error occurred in the optic unit The focus position set point is not within the permissible range
 3023 An error occurred in the optic unit The filter stepping motor cannot find the zero position
 3024 An error occurred in the optic unit The filter stepping motor cannot leave the zero position
 3025 A parameter set-up error occurred in the optic unit The filter number is not within the permissible range
 3026 A parameter set-up error occurred in the optic unit The number of the shaping element is not within the permissible range
 3027 An error occurred in the optic unit The adjust bias current of the laser diode is higher than the maximum current
 3028 An error occurred in the optic unit The maximum bias current of the laser diode is not sufficient to achieve the required light value
 3029 An error occurred in the optic unit The adjusted current of the laser diode is higher than the maximum current
 3030 A parameter set-up error occurred in the optic unit The modulation current of the laser diode set to maximum is not sufficient to achieve the required light value
 3031 An error occurred in the optic unit The laser diode must be on for the light stabilization
 3032 An error occurred in the optic unit The light stabilization must be off
 3033 An error occurred in the optic unit Passed value is to high for this function
 3034 An error occurred in the optic unit Passed value is to low for this function
 3050 On board device error Unable to set mirror power supply (36 V)
 3051 An error occurred in the slow scan unit The stepper board signals a short circuit, the safety loop is open or power supply (36V) failed
 3052 An error occurred in the slow scan unit The stepper board signals high temperature
 3053 An error occurred in the slow scan unit The stepper board signals not ready
 3054 An error occurred in the slow scan unit The carrier reaches the left limit
 3055 An error occurred in the slow scan unit The carrier reaches the right limit
 3056 An error occurred in the slow scan unit The carrier is moving when it is not allowed
 3057 An error occurred in the slow scan unit The safety loop is not closed
 3058 An error occurred in the slow scan unit An interrupt has occurred when not expected. Interrupt: Stop
 3059 An error occurred in the slow scan unit An interrupt has occurred when not expected. Interrupt: Signal of light barrier has changed
 3060 An error occurred in the slow scan unit An interrupt has occurred when not expected. Interrupt: Destination reached
 3061 An error occurred in the slow scan unit A SlowScan timeout is occurred during finding a position or moving into the light barrier
 3062 An error occurred in the slow scan unit A valid ramp could not be found
 3063 An error occurred in the slow scan unit A ramp which fits into a specified distance could not be found
 3064 A parameter error occurred The value of a parameter is not valid
 3078 An internal software error occurred An attempt to read an uninitialized ADC device.
 3088 An error occurred while material handling Timeout at build vacuum
 3089 An error occurred while material handling Timeout at vacuum off
 3138 An error occurred at punch init Punch not connected or not configured
 3159 An error occurred in the slow scan unit The safety loop is not closed
 3160 An error occurred in the slow scan unit The carrier reaches the left limit
 3161 An error occurred in the slow scan unit The carrier reaches the right limit
 3162 An error occurred in the slow scan unit The stepper board signals not ready
 3165 An error occurred while setting the light intensity The BaseIntensity value for the selected resolution of the current job is lower than the adjustable light
 3168 An error occurred in the slow scan unit The feed ramp could not be written
 3169 An error occurred in the slow scan unit Error while calculating feed ramp data
 3198 Not calibrated resolution selected The selected resolution is not calibrated. The BaseIntensity parameter for the selected resolution is zero
 3199 An communication error to the optic head occurred The communication to the optic head is broken
 3200 An communication error to the optic head occurred The communication to the optic head is faulty
 3201 An error occurred in the optichead unit The number of gate impulses generated by the Image-Control is out of range
 3202 An error occurred in the optichead unit The temperature of the laser diode did not change after switching on the temperature regulation
 3203 An error occurred in the optichead unit The temperature of the laser diode is over the maximum allowed temperature
 3204 An error occurred in the optichead unit A parameter transmitted to the optichead is out of range
 3205 An error occurred in the optichead unit A parameter transmitted to the optichead is out of range
 3206 An error occurred in the optichead unit An error without a defined event has occurred
 3207 An error occurred in the optichead unit The light value on the laser diode with the bias current alone is higher than the value in the application data. This may be due to an error in the primesetter or a not initialized material data set or an defective optichead
 3208 An error occurred in the optichead unit The error occurs if you switch on the temperature regulation on the optichead without a regulation device
 3209 An error occurred in the optichead unit The mirror phased out during transmission. The mirror is not locked
 3211 The mirror phased out during transmission. The mirror is not locked The detect vacuum is much too low
 3212 An error occurred while selecting the focus value The RIP transmitted resolution is not a element of the recorder resolution table
 3213 An error occurred while selecting the focus value The calculation of the spotshape value failed
 3214 An error occurred in the optic unit The calculation of the filter value failed
 3215 An error occurred in the optic unit The calculation of the physical focus value failed
 3216 An error occurred in the optic unit The calculation of the physical focus value failed
 3217 The safety loop was at least briefly interrupted 
 3226 An error occurred while setting the light intensity The BaseIntensity value for the selected resolution of the current job is lower than the adjustable light
 3227 An error occurred while setting the light intensity The BaseIntensity value for the selected resolution of the current job is higher than the adjustable light
 3228 An error occurred in the optichead unit The light value on the laser diode with the modulation current alone is to high . This may be due to an error in the primesetter or an defective optichead
 3229 An error occurred in the air supply unit The high-water sensor is still active, after water blow-off
 3230 An error occurred in the air supply unit The high-water sensor is still active, after water blow-off
 3238 Plate on table missing for load Possibly plate detector (on plate table) defect
 3239 An error occurred at punch action Timeout at punch action (10s) at arrive ls
 3240 An error occurred at material transport Timeout at drive plate slider to Down-Wait Position (prepare to load)
 3241 An error occurred at material transport Timeout at drive plate slider to Down-Free position (unload plate)
 3242 An error occurred at material transport Timeout at drive plate slider to Up-Unload Position (unload plate or init)
 3243 An error occurred at material transport Timeout at center plate on table
 3244 Plate on the table is not valid. Measured plate width is different to requested plate Plate on the table is not valid. Measured plate width is different to requested plate
 3245 Inserted plate is not valid. Measured plate length is different to requested plate Inserted plate is not valid. Measured plate length is different to requested plate
 3246 Unexpected plate on table detected. Exposed plate can not be ejected Unexpected plate on table detected. Exposed plate can not be ejected
 3247 An error occurred at material transport A timeout is occurred during moving the lift into a position. No interrupt occurred
 3248 There is no plate at the grip. Loading material isn't possible The plate sensor at the grip signals no-plate
 3249 An internal hardware error occurred The lift stepping motor cannot find it's zero position
 3250 An internal hardware error occurred. One or more fans at the back-wall don't work One or more of the guide fans at the back-wall don't work
 3251 An internal hardware error occurred. One or more fans at the back-wall don't work One or more of the guide fans at the back-wall don't work
 3252 An internal hardware error occurred. One or more fans at the back-wall don't work One or more of the guide fans at the back-wall don't work
 3253 An internal hardware error occurred. One or more fans at the back-wall don't work One or more of the guide fans at the back-wall don't work
 3254 The safety loop is open The safety loop is open
 3255 An internal hardware error occurred An internal hardware error occurred
 3256 An internal hardware error occurred An internal hardware error occurred
 3258 Plate position in lift is not valid for unloading Inserted plate is not valid. Measured plate length is different to requested plate
 3259 An error occurred at material transport An error occurred at material transport
 3260 An error occurred at material transport Moving the flaps failed. They didn't reach their in-or-out target position
 3261 An error occurred at material transport Moving the flaps failed. They didn't reach their in-or-out target position
 3262 An error occurred at material transport Lift didn't reach it's set position. Maybe stopped by a sporadic interrupt
 3263 An error occurred at material transport Moving the lift isn't possible because the flaps stays in the path
 3264 An error occurred at material transport Moving the lift isn't possible because the grip unit is in horizontal position
 3265 An error occurred at material transport There are no valid parameter available
 3266 An error occurred at material transport Lift lost it's position. Lower reference light-barrier shows a position error bigger than 1.2mm 
 3267 Material Length isn't possible to load It isn't possible to move the lift into the calculated load position for this material length
 3269 An error occurred at material transport This operation isn't possible at this time because the system wasn't initialized correctly 
 3270 The set lift position is out of range It isn't possible to move the lift into the calculated load position for this material length 
 3271 An error occurred at material transport There are no valid parameter available 
 3272 An error occurred at material transport Initializing of the lift not possible - maybe the grip is still under the hooks in the indrum 
 3274 An error occurred in the lift and grip unit The stepper board signals not ready
 3275 An error occurred in the lift and grip unit The lift ramp could not be written
 3276 An error occurred in the lift and grip unit Error while calculating lift ramp data
 3277 An error occurred in the lift and grip unit Moving the lift isn't possible because the flaps stays in the path
 3278 An error occurred in the lift and grip unit FPGA and Parameter Grip Mode do not match
 3279 part of the covering isn't closed correctly or the emergency switch is activated 
 3280 Exposed plate is keeping in recorder Exposed plate is keeping in recorder
 3281 The service switch bypasses the safety loop 
 3286 Unexpected plate on table detected. Init recorder or error correction not possible Unexpected plate on table detected. Init recorder or error correction not possible
 3287 An error occurred in the lift and grip unit The lift stepping motor cannot find it's zero position
 3288 An internal hardware error occurred. One or more fans at the plate-table don't work One or more of the guide fans at the plate-table don't work
 3289 An internal hardware error occurred. One or more fans at the plate-table don't work One or more of the guide fans at the plate-table don't work
 3296 Voltage failure  The negative analog 5 V failed 
 3297 Voltage failure  The negative analog 5 V failed 
 3298 Voltage failure  The negative analog 5 V failed 
 3299 Voltage failure  The positive 36 V failed 
 3300 Voltage failure  The positive 15 V failed
 3301 Voltage failure  The positive 42 V failed
 3302 Voltage failure  The positive 7.5 V failed 
 3303 Voltage failure  The positive 7.5 V failed 
 3304 Voltage failure  The positive analog 24 V failed 
 3305 Voltage failure  The positive 3.3 V failed 
 3306 Voltage failure  The positive 2.5 V failed 
 3307 The positive 2.5 V failed  Safety loop check failed. Check the Logfile for further information
 3309 An error occurred in the material base The requested material does not exist
 3310 An error occurred at material transport The plate center unit does not left the light barrier
 3311 An error occurred at material transport An unexpected motor stop from stepper counter at plate centering
 3312 An error occurred in the air supply unit The air pressure did not reach the required minimum
 3315 The aging of the laser diode has accelerated Too few exposure time has elapsed since the last automatic increase of the bias current setvalue. Nevertheless the bias current setvalue will be increased
 3316 The end of lifetime of the laser diode is approaching The nominal maximum limit of the total current of the laser diode has been reached
 3317 An error occurred in the air supply unit The mirror air pressure is above stop-limit
 3318 An error occurred in the air supply unit The mirror air pressure is above stop-limit
 3325 An error occurred in the material base. The preferred shaft has not been specified The preferred shaft is used in case a material shall be loaded which gets no link from any shaft
 3326 An error occurred in the material base The name of the material that is send with the command request material is invalid
 3327 Remove Plate from table. Plate is exposed Remove Plate from table
 3328 Remove Plate from table. Plate is unexposed Remove plate from manual tray
 3329 OLP program change necessary OLP program change necessary
 3913 Autoloader error state detected Autoloader error state detected
 3914 Internal software or parameter error Syntax error in debug configuration
 3915 The Emergency Switch is activated 
 3916 The boot sequence failed. Please reboot the system The boot sequence failed. Please reboot the system
 4001 Internal software or parameter error Syntax error in debug configuration
 4002 Execution error - A general STOP occurred A general BREAK occurred
 4003 Internal error - sensor not recognized A sensor in the device does not respond
 4004 Internal error - setting a sensor failed Writing to a sensor failed
 4005 Internal error - actuator not recognized An actuator in the device does not respond
 4006 An actuator in the device does not respond Writing to an actuator failed
 4007 Error checking the Cassette/Waste safety loop There is a problem with the safety loop of the Cassette / Waste section. Checking it failed
 4008 Invalid Autoloader machine type set 
 4009 Any part of the covering isn't closed correctly 
 4010 The safety loop was at least briefly interrupted 
 4011 The service switch bypasses the safety loop 
 4012 Internal system error Error using operating system function
 4013 Error checking the cover safety loop There is a problem with the safety loop of the cover section. Checking it failed
 4014 Runtime error Internal software error
 4015 The Emergency Switch is activated 
 4016 The boot sequence failed. Please reboot the system The boot sequence failed. Please reboot the system
 4100 Error separating a plate 
 4101 Error initializing the shutter Unable to access the shutter init sensor
 4102 Error initializing the shutter Unable to quit the shutter init sensor
 4103 Error moving the shutter Unable to move the shutter into waste position
 4104 Error moving the shutter The shutter failed to get to the material transfer position
 4105 Error polling a load table plate sensor Load table plate sensor on the suction cart not found
 4106 Error separating Plate lost while separating or during transport to the entry of the load table plate. The plate did not arrive at the relevant sensor
 4107 Error placing the plate on the load table plate Plate lost during transport to the load table plate, the table plate sensor on the suction cart fails to detect the plate at the end of the transfer process
 4108 Error moving the shutter Separator exit sensor not left when transporting the plate to the load table plate
 4109 Paper sheet lost when separating When depositing the paper sheet, the vacuum shows that the sheet was lost during transfer into the waste container
 4110 Error initializing the stripper unit Stripper unit did not arrive at the init position during initialization
 4111 Error initializing the stripper unit Unable to quit the init sensor of the stripper unit
 4112 Error moving the stripper unit into working position Unable to quit the parking sensor of the stripper unit
 4113 Error moving the stripper unit Unable to get to the parking sensor of the stripper unit
 4115 Moving the stripper unit into the parking position caused an error several times Moving the stripper unit into the parking position caused an error several times
 4116 A sensor was not reached while the stripper unit was moving to its park position The light barrier of the park sensor was not detected while the stripper unit was moving to its park position
 4117 A sensor was not reached during initialization of the stripper unit The light barrier of the park sensor was not detected during initialization of the stripper unit
 4118 A sensor was not reached during normalization of the shutter A sensor was not reached during normalization of the shutter
 4119 A sensor was not reached during initialization of the shutter The zero light barrier was not detected during initialization of the shutter
 4120 Error initializing the cassette shutter Cassette shutter motor did not arrive at the init position during initialization
 4121 Error initializing the cassette shutter Unable to quit the init position when initializing the cassette shutter motor
 4122 Error while preparing cassette shade drive for taking a new cassette Sensor could not detect the requested phase 1 during the specified number of attempts during initialization of the cassette shade drive
 4123 Error while preparing cassette shade drive for taking a new cassette Sensor could not detect the requested phase 2 during the specified number of attempts during initialization of the cassette shade drive
 4124 A sensor was not reached during initialization of the cassette shade drive The light barrier of the close sensor was not detected during initialization of the cassette shade drive
 4130 Error moving the suck bar The suck bar did not arrive in its new position during the expected time
 4133 Error lowering the suck bar The suck bar is not at its bottom position as expected
 4134 Error moving the suck bar The suck bar is not at the middle position as expected
 4135 Error lifting the suck bar The suck bar is not at the top position as expected
 4136 Error moving the suck bar The suck bar does not move
 4137 Error setting the suck bar parameters A command to the suck bar returned an invalid command
 4138 While separating, double sheet error Paper under plate occurred several times without a plate being present While separating, double sheet error Paper under plate occurred several times without a plate being present
 4139 A piece of paper, located on the Jalousie, couldn't fix by the suck bar A piece of Paper couldn't move from the suck bar to the Jalousie suction bar
 4140 Error setting the separator ejector parameters Invalid command encountered when enabling the ejector's blowing function
 4141 Error setting the separator ejector parameters Invalid command encountered when enabling the ejector's suction function
 4142 Error setting the separator ejector parameters Invalid command encountered when actuating the compressed air supply of the ejector's suck bar
 4143 Error setting the separator ejector parameters Invalid command encountered when actuating the compressed air supply of the ejector's suction bar
 4144 Vacuum error signaled by vacuum sensor. Unable to suck and hold the material or material lost The vacuum sensor of the separator detected an insufficient vacuum
 4152 Error setting the double sheet sensor parameters Invalid command encountered when selecting the double sheet sensor
 4153 No or not enough compressed air Poll of compressed air status result: no compressed air
 4154 Error separating. A double sheet detected cannot be separated because the suction bar is carrying material already 
 4155 A double sheet detected on the jalousie. The material could not be separated The double sheet must be removed manually by hand
 4156 A double sheet was detected on the Jalousie. The material couldn't be split The double sheet couldn't fix by the suck bar - it must be removed by hand
 4157 A double sheet was detected on the Jalousie. The material couldn't be split The double sheet couldn't fix by the suck bar - it must be removed by hand
 4161 Tray empty. No material on the active tray No material found when reading the tray fill level
 4162 A detected double sheet on the Jalousie couldn't move to the Load Table A double sheet wasn't detected from the exit-sensor of the separator
 4163 A double sheet was detected on the Jalousie. The material couldn't be split within several tries The double sheet couldn't be split within several tries - it must be removed by hand
 4164 While checking the material at the suction bar, an error with the vacuum occurred 
 4165 While sucking the paper with the suck bar, a vacuum error occurred There was no vacuum at the suction bar
 4166 The paper could not be removed, because the cassette was not open 
 4167 While loading and locking the cassette an error occured inside the SCL 
 4171 Clamp jaw unit error Unable to close the clamp jaw
 4172 Clamp jaw unit error Unable to open the clamp jaw unit - the unit will not release the plate
 4173 Error closing the clamp jaw unit Unable to close the clamp jaw unit during the expected time
 4174 Error closing the clamp jaw unit Unable to open the clamp jaw unit during the expected time
 4181 No material found in the cassette No material was detected during check of cassette level
 4182 Almost no material in the cassette A check of the cassette level detected only a few plates still in the cassette. The number has fallen below the set alert level
 4183 The waste container is full A check of the waste container level detected that the container is full
 4184 The waste container is almost full A check of the waste container level detected that the set alert level was exceeded
 4190 Error setting the waste container parameters Invalid command encountered when opening / closing the waste container
 4191 Unable to open the waste container The waste container could not be opened because it was impossible to move the shutter into the specified position
 4192 Waste container open Could not open the cassette because the waste container was not closed
 4193 Vacuum error at the suction bar. Could not suck the material to the bar or the material was lost Vacuum sensor detected that the vacuum was too low when the suction bar of the separator was used
 4194 Vacuum error after raising the suction bar. Could not suck the material to the bar or the material was lost Vacuum sensor detected that the vacuum was too low after raising the suction bar
 4195 Configuration error - unknown machine type Invalid machine type set
 4196 Error separating Plate lost while separating or during transport to the entry of the load table plate. The plate did not arrive at the relevant sensor
 4197 Error separating Material lost when lifting it out of the tray
 4198 An error occurred during initialization or error handling. Material was found on the shutter Material was found on the shutter during initialization or error handling. The material is to be removed by the operator
 4201 Unable to determine the position of the load table plate Both load table plate position sensors output the same signal
 4202 Error moving the load table Timeout encountered when swivelling/moving the load table
 4203 The load table fans are not working 
 4204 Error moving the plate holder Timeout encountered when lifting/lowering the plate holder
 4205 Error initializing the plate holder The plate holder did not move away from its init sensor
 4206 Error initializing the plate drive motor The plate holder did not move up to its init sensor
 4207 Error initializing the plate drive motor Initialization of the plate drive motor failed. Absolute positioning of the plate holder is not possible
 4208 No plate on the load table The procedure requires a plate but none has been detected
 4209 Error initializing the center unit The center unit did not move away from its init sensor
 4210 Error initializing the center unit The center unit did not move up to its init sensor
 4211 Material transport error Error transporting the plate from the load table to the conveyor
 4212 Plate not in the gripper The plate did not move up to the grip sensor
 4213 The plate did not move up to the grip sensor Wrong width of plate. See the log file for further details
 4214 Load table process error A signal expected from the load table holder sensor not received
 4215 Error initializing the load table The states of the load table sensors have been checked. The result is an impossible combination
 4226 Double sheet detected on load table during material transport to recorder Please remove the material manually by hand
 4227 The load table can not be moved, because material was detected between separator and load table Material was detected in light barrier of the separator. The material is to be removed by the operator before moving the load table
 4301 Error moving the conveyor Timeout lifting/lowering the conveyor table
 4302 Error initializing the conveyor roller motor Initialization of the conveyor roller motor failed
 4303 Error transporting the plate from the conveyor to the load table Plate transport from the conveyor to the load table is not possible. The plate has left the range of the entry sensor already
 4304 Error centering the plate on the conveyor Unable to fully load the plate onto the conveyor. The conveyor entry sensor is not free
 4305 No plate on the conveyor The procedure requires a plate but none has been detected
 4306 Configuration error - no valid assembly position of the online processor Assembly position of the online processor wrong or not specified
 4307 Error centering the plate on the conveyor Conveyor center sensor not enabled
 4308 Error initializing the conveyor slider The conveyor slider did not move away from its init sensor
 4309 Error initializing the conveyor slider The conveyor slider did not move up to its init sensor
 4310 Error initializing the conveyor slider Initialization of the conveyor slider motor failed
 4311 Error unloading the plate Signal expected from the conveyor entry sensor not received
 4312 Conveyor process error Signal expected from the conveyor slider init sensor not received
 4313 Error actuating the online processor No ON signal of the online processor
 4314 Error actuating the online processor No connect signal of the online processor
 4315 Configuration error - wrong online processor interface set The set online processor interface is unknown
 4316 Error unloading the plate Error centering the plate on the conveyor. The computed correction exceeds the maximum
 4317 Error unloading the plate Signal expected from the conveyor exit sensor not received
 4318 Error unloading the plate Signal expected from the conveyor center sensor not received
 4319 Error initializing the conveyor The states of the conveyor sensors have been checked. The result is an impossible combination
 4320 Error centering the plate on the conveyor Unable to readjust the plate onto the conveyor. The plate is expected on the entry sensor but isn't there
 4401 An error occurred while swinging out the cassette drive One of the two cassette drives did not reach its swing-out position in the allotted time
 4402 An error occurred while swinging out the cassette drive One of the two cassette drives did not leave its swing-out position in the allotted time
 4403 An error occurred during the cassette drive setup An invalid command for the cassette drive was detected
 4404 An error occurred while evaluating the current cassette position The sensors for the horizontal cassette position returned an invalid position
 4405 No cassette was detected at the MCL exit when conveying a cassette from the SCL to the MCL The exit sensor of the MCL did not detect a cassette
 4406 No cassette was detected at the MCL entry when loading a cassette The cassette drive sensor (perhaps the entry sensor as well) did not detect a cassette
 4407 No fully loaded cassette was detected while unloading a cassette from the MCL 
 4408 A cassette could not be positioned correctly while loading it from the SCL The specified number of attempts to position the cassette was exceeded
 4409 A cassette could not be positioned correctly while loading it from the trolley The specified number of attempts to position the cassette was exceeded
 4410 Error closing the inlet door The inlet door did not reach the position in the allotted time
 4411 Error opening the inlet door The inlet door did not reach the position in the allotted time
 4412 An error occurred while evaluating the current inlet door position The sensors for the inlet door position returned an invalid position
 4413 An error occurred during the setup of the inlet door drive An invalid command for the inlet door drive was detected
 4414 The inlet door was not open before a cassette was unloaded to the trolley 
 4415 The inlet door was not closed before the elevator moved 
 4420 Error initializing the elevator The elevator init sensor was not reached
 4421 Error initializing the elevator The elevator init sensor was not left
 4422 An error occurred while evaluating the current elevator position The sensors for the vertical cassette position detected an invalid position
 4423 Failed to find cause of aborted movement after elevator or cassette drive finished moving The cause was an undefined event
 4424 The elevator or cassette drive did not finish moving by reaching a sensor 
 4425 An error occurred while moving the elevator The error bit of the elevator motor is active
 4426 A safety error occurred before the elevator moved One of the two cassette drives is not swung out
 4427 A safety error occurred before the elevator moved The cassette in the SCL was not locked
 4428 An error occurred while evaluating the current elevator position The sensors for the vertical cassette position returned an invalid position
 4429 An error occurred during the elevator setup An invalid command for the elevator was detected
 4440 No fully loaded cassette was detected before unloading a cassette from the MCL to the SCL or the trolley 
 4441 No fully loaded cassette was detected after loading a cassette from the SCL or the trolley  to the MCL 
 4442 No cassette was detected at the MCL entry sensor before loading a cassette from the SCL to the MCL 
 4443 No cassette was detected at the MCL exit sensor after unloading a cassette from the MCL to the SCL 
 4444 No cassette was detected at the MCL entry sensor before loading a cassette from the trolley to the MCL 
 4445 No cassette was detected at the MCL entry sensor after unloading a cassette from the  MCL to the trolley 
 4446 A cassette was detected to be not fully loaded to its position before the elevator moved 
 4447 The cassette is not in valid position 
 4448 No trolley was found in front of the MCL before unloading a cassette from the MCL 
 4449 A cassette was detected in the SCL before unloading a cassette from the MCL to the SCL 
 4450 The elevator could not be moved or movement had to be stopped too soon because the cassette drive was no longer swung out 
 4451 An error occurred, at least one safety relay of the MCL is open 
 4460 Movement of elevator started, duration approximately 90 sec 
 4461 Movement of elevator started, duration approximately 60 sec 
 4462 Movement of elevator started, duration approximately 30 sec 
 4500 No tray with the requested material Further processing will be paused until a tray with the requested material has been put in
 4501 The waste container is open Further processing will be paused until the waste container has been closed
 4502 The load table is not free. The system may be waiting for a plate to be moved on into the online processor Further processing will be paused until the load table is free again
 4503 The conveyor is not free. The system may be waiting for a plate to be moved on into the online processor Further processing will be paused until the conveyor is free again
 4504 The trolley is not in loading/unloading position Further processing will be paused until the trolley is in the correct position
 4505 Online processor not ready - no connect signal Further processing will be paused until a connect signal has been received from the online processor
 4506 The online processor is off Further processing will be paused until the online processor is on and has sent a ready signal
 4507 The online processor is busy Further processing will be paused until the state of the online processor has changed from Busy to Not Busy
 4508 The paper container is full Further processing will be paused until the paper container has been opened and emptied
 4509 Tray empty Further processing will be paused until the tray has been removed, filled with material and put back in
 4510 No or not enough compressed air Further processing will be paused until the pressure level has reached the required value
 4511 Remove the cassette Further processing will be paused until the cassette has been removed
 4512 Insert required plate to bypass Insert required plate to bypass
 4513 Remove plate from bypass. Plate width is not as requested Remove plate from bypass
 4520 Shaft data inconsistency detected. Rescan initiated (approx. 120 sec.) 
 4530 Error executing comand The DAL command is not implemented
 4531 Error executing command The DAL command was rejected
 4532 Error loading/unloading a cassette Loading/unloading the cassette to the specified tray was impossible as the tray already contained a cassette
 4533 Error loading/unloading a cassette The specified tray number is out of ra
 4534 Error loading/unloading a cassette The specified tray type is incorrect
 4535 Error loading/unloading a cassette The state of the specified tray is incorrect
 4536 Initialization failed The initialization loop exceeded the maximum
 4537 Error Correction failed The error correction loop exceeded the maximum
 4538 Shut down failed The shutdown loop exceeded the maximum
 4988 An error was detected in the horizontal drive of the MCL The elevator's motor control detected an error and switched itself off
 4989 Error initializing a motor Unable to quit the home sensor
 4990 Error initializing a motor Expected home sensor not found at the target position
 4991 Error controlling a motor Expected sensor not found at the target position
 4992 Error controlling a motor Invalid parameter found when computing the data for stepper motor actuation
 4993 Error controlling a motor No actuation data found when starting the stepper motor
 4994 Error controlling a motor Insufficiently larger memory range found when computing the data for stepper motor actuation
 4995 Error controlling a motor Absolute motor positioning not possible, the motor is to be initialized first
 4996 Error controlling a motor Timeout actuating the stepper motor
 4997 Error controlling a motor Invalid minimum frequency for actuating the stepper motor
 4998 Error controlling a motor Invalid parameter found when computing the data for stepper motor actuation
 4999 Error controlling a motor Error computing the data for actuating the stepper motor